Skip to main content

Table 4 Inlet values and percentage removal (%R) of nutrients monitored on monthly basis for hydroponic treatment units (HUs) and control unit (CTRL)

From: Suitability of nutrients removal from brewery wastewater using a hydroponic technology with Typha latifolia

Parameter

Description

Time (month)

23-May-15

23-Jun-15

23-Jul-15

23-Aug-15

23-Sep-15

23-Oct-15

23-Nov-15

TKN

Inlet (in mg l−1)

19

43

35

28

41

29

38

Outlet

HUs (%R)

72

79

80

59

72

70

54

CTRL (%R)

42

42

34

38

41

41

45

NH4+-N

Inlet (in mg l−1)

18

24

27

31

20

23

25

Outlet

HUs (%R)

42

54

56

65

45

54

51

CTRL (%R)

22

25

33

26

20

13

32

NO3−-N

Inlet (in mg l−1)

16

9.8

11.8

17

13

8.7

14.8

Outlet

HUs (%R)

47

56

58

47

54

47

50

CTRL (%R)

25

31

32

24

23

23

26

PO4−3-P

Inlet (in mg l−1)

13

11

16

14

8

19

23

Outlet

HUs (%R)

59

56

63

70

57

51

53

CTRL (%R)

23

27

40

37

20

35

39