Skip to main content

Table 6 Comparison of general applicability and practicability of the designed assays

From: Comparison of different real-time PCR chemistries and their suitability for detection and quantification of genetically modified organisms

 

Modified probes

Modified primers

Investigated characteristic

TaqMan®a

LNA®

CPT

Lux™

Plexor™

Labour intensity to design

low

low

middle

high

middle

Primer/probe design

software

on demand

on demand

software

software

Redesigns required (No. of unsuccessful/successful designs)

-

0/2

1/2

3/4

1/4

Price to establish a new system

high

high

very high

middle

middle

Price for 100 × 10 μl reactions in Eurosa

46

48

185

50

42

Run duration (minutes)

120

120

84

144

87

Labour intensity to analyze

low

low

low

middle

middle

  1. a Well established TaqMan® based amplicons were analyzed in parallel as a reference system. b Estimated costs include PCR reagent, primers and probes but exclude plastics and optical covers since they are the same for all tests. Prices are stated for Slovenia, European Union, and may differ in other countries.